  • Festo SBRD-Q/SBOC-Q/SBOI-Q

    View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Festo Equipment: SBRD-Q/SBOC-Q/SBOI-Q Vulnerabilities: Incorrect Conversion between Numeric Types, Out-of-bounds Read, Reachable Assertion 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow the attacker to read arbitrary data or cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Festo… Read more

  • LG Innotek Camera Multiple Models

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/Low attack complexity Vendor: LG Innotek Equipment: Camera Models LND7210 and LNV7210R Vulnerability: Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain administrative access to the device. 3. TECHNICAL DETAILS 3.1 AFFECTED… Read more

  • CISA Releases Two Industrial Control Systems Advisories

    CISA released two Industrial Control Systems (ICS) advisories on October 7, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-280-01 Delta Electronics DIAScreen ICSA-25-226-31 Rockwell Automation 1756-EN4TR, 1756-EN4TRXT (Update B) CISA encourages users and administrators to review newly released ICS advisories for technical details and mitigations. Read more

  • Rockwell Automation FactoryTalk Action Manager

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Action Manager Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local unauthenticated attacker to listen to communications and manipulate the device. 3. TECHNICAL DETAILS 3.1 AFFECTED… Read more

  • Rockwell FactoryTalk Linx

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Rockwell Equipment: FactoryTalk Linx Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to to create, update, and delete FTLinx drivers. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Rockwell Automation products are affected: FactoryTalk… Read more

  • Siemens BFCClient

    As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack… Read more

  • Siemens SINEC OS

    As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3.1 9.1 ATTENTION: Exploitable remotely/low attack… Read more

  • CISA Adds One Known Exploited Vulnerability to Catalog

    CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation.  CVE-2025-54948 Trend Micro Apex One OS Command Injection Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.  Binding Operational Directive (BOD) 22-01: Reducing the Significant… Read more

  • Siemens Engineering Platforms

    As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.2 ATTENTION: Low Attack Complexity… Read more

  • Siemens RUGGEDCOM ROX II

    As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.1 ATTENTION: Exploitable remotely/low attack… Read more