Our news
-
Hitachi Energy Relion 670/650 and SAM600-IO Series
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: Relion 670/650 and SAM600-IO Vulnerability: Allocation of Resources Without Limits or Throttling 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to cause a denial-of-service that disrupts critical functions in the device. 3. TECHNICAL DETAILS 3.1
-
FESTO Automation Suite, FluidDraw, and Festo Didactic Products
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: FESTO, FESTO Didactic Equipment: CIROS Studio / Education, Automation Suite, FluidDraw, FluidSIM, MES-PC Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to gain full control of the host system, including remote code execution. 3.
-
FESTO Hardware Controller, Hardware Servo Press Kit
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: FESTO Equipment: Hardware Controller, Hardware Servo Press Kit Vulnerabilities: Improper Neutralization of Special Elements used in an OS Command (‘OS Command Injection’) 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute unauthorized system commands with root
-
Hitachi Energy MSM
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: Modular Switchgear Monitoring (MSM) Vulnerability: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’) 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to execute untrusted code, potentially leading to unauthorized actions or system compromise.
-
FESTO CODESYS
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: FESTO Equipment: CODESYS Vulnerabilities: Partial String Comparison, Uncontrolled Resource Consumption, Memory Allocation with Excessive Size Value 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to block legitimate user connections, crash the application, or authenticate without proper credentials.
-
Voltronic Power and PowerShield UPS Monitoring Software
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Voltronic Power, PowerShield Equipment: Viewpower, NetGuard Vulnerabilities: Exposed Dangerous Method or Function, Forced Browsing 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthenticated attacker remotely to make configuration changes, resulting in shutting down UPS connected devices or execution
-
CISA Adds One Known Exploited Vulnerability to Catalog
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-6543 Citrix NetScaler ADC and Gateway Buffer Overflow Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant
-
CISA and Partners Urge Critical Infrastructure to Stay Vigilant in the Current Geopolitical Environment
Today, CISA, in collaboration with the Federal Bureau of Investigation (FBI), the Department of Defense Cyber Crime Center (DC3), and the National Security Agency (NSA), released a Fact Sheet urging organizations to remain vigilant against potential targeted cyber operations by Iranian state-sponsored or affiliated threat actors. Over the past several months, there has been increasing
-
Mitsubishi Electric Air Conditioning Systems
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: Air conditioning systems Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to control the air conditioning system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Mitsubishi Electric reports the following