Our news
AutomationDirect C-more EA9 HMI
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: AutomationDirect Equipment: C-more EA9 HMI Vulnerability: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition or achieve remote code execution on the affected…
CISA Partners with ASD’s ACSC, CCCS, NCSC-UK, and Other International and US Organizations to Release Guidance on Edge Devices
CISA—in partnership with international and U.S. organizations—released guidance to help organizations protect their network edge devices and appliances, such as firewalls, routers, virtual private networks (VPN) gateways, Internet of Things (IoT) devices, internet-facing servers, and internet-facing operational technology (OT) systems. The published guidance is as follows: “Security Considerations for Edge Devices,” led by the Canadian…
Schneider Electric Web Designer for Modicon
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Schneider Electric Equipment: Web Designer for Modicon Vulnerability: Improper Restriction of XML External Entity Reference 2. RISK EVALUATION Successful exploitation of this vulnerability could result in information disclosure, workstation integrity and potential remote code execution on the compromised computer. 3. TECHNICAL DETAILS…
Schneider Electric Pro-face GP-Pro EX and Remote HMI
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.1 ATTENTION: Exploitable remotely Vendor: Schneider Electric Equipment: Pro-face GP-Pro EX and Remote HMI Vulnerability: Improper Enforcement of Message Integrity During Transmission in a Communication Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow man-in-the-middle attacks, resulting in information disclosure, integrity issues, and operational failures. 3.…
Schneider Electric Modicon M340 and BMXNOE0100/0110, BMXNOR0200H
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Modicon M340 and BMXNOE0100/0110, BMXNOR0200H Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could cause information disclosure of a restricted web page, modification of a web page, and a…
CISA Releases Nine Industrial Control Systems Advisories
CISA released nine Industrial Control Systems (ICS) advisories on February 4, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-035-01 Western Telematic Inc NPS Series, DSM Series, CPM Series ICSA-25-035-02 Rockwell Automation 1756-L8zS3 and 1756-L3 and 1756-L3 ICSA-25-035-03 Elber Communications Equipment ICSA-25-035-04 Schneider Electric Modicon M580 PLCs, BMENOR2200H…
Western Telematic Inc NPS Series, DSM Series, CPM Series
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Western Telematic Inc Equipment: NPS Series, DSM Series, CPM Series Vulnerability: External Control of File Name or Path 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated attacker to gain privileged access to files on the device’s filesystem.…
Rockwell Automation 1756-L8zS3 and 1756-L3 and 1756-L3
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: 1756-L8zS3, 1756-L3zS3 Vulnerability: Improper Handling of Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote, non-privileged user to send malicious requests resulting in a major nonrecoverable fault causing a denial-of-service condition. 3. TECHNICAL…
Schneider Electric Modicon M580 PLCs, BMENOR2200H and EVLink Pro AC
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Modicon M580 PLCs, BMENOR2200H and EVLink Pro AC Vulnerability: Incorrect Calculation of Buffer Size 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service of the product when an unauthenticated user sends a crafted HTTPS packet…
Elber Communications Equipment
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Elber Equipment: Communications Equipment Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Hidden Functionality 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker unauthorized administrative access to the affected device. 3. TECHNICAL DETAILS 3.1…