Fuji Electric Monitouch V-SFT
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Fuji Electric Equipment: Monitouch V-SFT Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could crash the device being accessed. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following version of Fuji Electric’s Monitouch V-SFT, a screen configuration software, is affected:…
-
Ruijie Reyee OS
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Ruijie Equipment: Reyee OS Vulnerabilities: Weak Password Recovery Mechanism for Forgotten Password, Exposure of Private Personal Information to an Unauthorized Actor, Premature Release of Resource During Expected Lifetime, Insecure Storage of Sensitive Information, Use of Weak Credentials, Improper Neutralization of Wildcards…
-
Fuji Electric Tellus Lite V-Simulator
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Fuji Electric Equipment: Tellus Lite V-Simulator Vulnerabilities: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could crash the device being accessed. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS VS5Sim is a simulator of V-SFT Ver5 packaged with Fuji Electric Tellus Lite…
-
Siemens RUGGEDCOM APE1808
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity…
-
CISA Releases Eight Industrial Control Systems Advisories
CISA released eight Industrial Control Systems (ICS) advisories on December 3, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-338-01 Ruijie Reyee OS ICSA-24-338-02 Siemens RUGGEDCOM APE1808 ICSA-24-338-03 Open Automation Software ICSA-24-338-04 ICONICS and Mitsubishi Electric GENESIS64 Products ICSA-24-338-05 Fuji Electric Monitouch V-SFT ICSA-24-338-06 Fuji Electric Tellus Lite…
-
Open Automation Software
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Open Automation Software Equipment: Open Automation Software Vulnerability: Incorrect Execution-Assigned Permissions 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker executing code with escalated privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Open Automation Software,…
-
CISA Releases Six Industrial Control Systems Advisories
CISA released six Industrial Control Systems (ICS) advisories on November 26, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-331-01 Schneider Electric PowerLogic PM55xx and PowerLogic PM8ECC ICSA-24-331-02 Schneider Electric PowerLogic P5 ICSA-24-331-03 Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340, M580 and M580 Safety…
-
Hitachi Energy RTU500 Scripting Interface
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.4 ATTENTION: Exploitable remotely Vendor: Hitachi Energy Equipment: RTU500 Scripting Interface Vulnerability: Improper Certificate Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to spoof the identity of the service. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Hitachi Energy are affected: RTU500…
-
Schneider Electric PowerLogic P5
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION: Low attack complexity Vendor: Schneider Electric Equipment: PowerLogic P5 Vulnerability: Use of a Broken or Risky Cryptographic Algorithm 2. RISK EVALUATION If an attacker has physical access to the device, it is possible to reboot the device, cause a denial of service condition, or gain full…
-
Hitachi Energy MicroSCADA Pro/X SYS600
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: MicroSCADA Pro/X SYS600 Vulnerabilities: Improper Neutralization of Special Elements in Data Query Logic, Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’), Authentication Bypass by Capture-replay, Missing Authentication for Critical Function, URL Redirection to Untrusted Site…