Hitachi Energy TropOS Devices Series 1400/2400/6400
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: TropOS Devices Series 1400/2400/6400 Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Hitachi Energy are
-
ThreatQuotient ThreatQ Platform
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: ThreatQuotient Inc. Equipment: ThreatQ Platform Vulnerability: Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to perform remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ThreatQuotient ThreatQ Platform, are affected: ThreatQ
-
Schneider Electric Modicon
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Modicon M241 / M251 / M258 / LMC058 Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to a denial-of-service and a loss of confidentiality and integrity in the controller. 3. TECHNICAL DETAILS
-
Rockwell Automation PowerMonitor 1000 Remote
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: PowerMonitor 1000 Remote Vulnerabilities: Unprotected Alternate Channel, Heap-based Buffer Overflow, Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform edit operations, create admin users, perform factory reset, execute arbitrary code,
-
BD Diagnostic Solutions Products
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.0 ATTENTION: Low attack complexity Vendor: Becton, Dickinson and Company (BD) Equipment: Diagnostic Solutions Products Vulnerability: Use of Default Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to use default credentials to access, modify, or delete sensitive data, which could impact the availability
-
CISA Releases Five Industrial Control Systems Advisories
CISA released five Industrial Control Systems (ICS) advisories on December 17, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-352-01 ThreatQuotient ThreatQ Platform ICSA-24-352-02 Hitachi Energy TropOS Devices Series 1400/2400/6400 ICSA-24-352-03 Rockwell Automation PowerMonitor 1000 Remote ICSA-24-352-04 Schneider Electric Modicon ICSMA-24-352-01 BD Diagnostic Solutions Products CISA encourages users
-
CISA Adds Two Known Exploited Vulnerabilities to Catalog
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation. CVE-2024-20767 Adobe ColdFusion Improper Access Control Vulnerability CVE-2024-35250 Microsoft Windows Kernel-Mode Driver Untrusted Pointer Dereference Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive
-
CISA Requests Public Comment for Draft National Cyber Incident Response Plan Update
Today, CISA—through the Joint Cyber Defense Collaborative and in coordination with the Office of the National Cyber Director (ONCD)—released the National Cyber Incident Response Plan Update Public Comment Draft. The draft requests public comment on the National Cyber Incident Response Plan (NCIRP)—public comment period begins today and concludes on January 15, 2025. Since initial publication