  • CISA Releases Six Industrial Control Systems Advisories

    CISA released six Industrial Control Systems (ICS) advisories on June 11, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-163-01 Rockwell Automation ControlLogix, GuardLogix, and CompactLogix ICSA-24-163-02 AVEVA PI Web API ICSA-24-163-03 AVEVA PI Asset Framework Client ICSA-24-163-04 Intrado 911 Emergency Gateway ICSA-23-108-02 Schneider Electric APC Easy UPS… Read more

  • Rockwell Automation ControlLogix, GuardLogix, and CompactLogix

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.3 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: ControlLogix, GuardLogix, CompactLogix Vulnerability: Always-Incorrect Control Flow Implementation 2. RISK EVALUATION Successful exploitation of this vulnerability could compromise the availability of the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports that the following controllers are affected: ControlLogix… Read more

  • Johnson Controls Software House iStar Pro Door Controller

    View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Johnson Controls Inc. Equipment: Software House iStar Pro Door Controller, ICU Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker to perform a machine-in-the-middle attack to inject commands which change configuration or… Read more

  • Emerson PACSystem and Fanuc

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.6 ATTENTION: Low attack complexity Vendor: Emerson Equipment: PACSystem, Fanuc Vulnerabilities: Cleartext Transmission of Sensitive Information, Insufficient Verification of Data Authenticity Insufficiently Protected Credentials, Download of Code Without Integrity Check CISA is aware of a public report, known as “OT:ICEFALL”, detailing vulnerabilities found in multiple operational technology (OT)… Read more

  • Emerson Ovation

    View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Emerson Equipment: Ovation Vulnerabilities: Missing Authentication for Critical Function, Insufficient Verification of Data Authenticity CISA is aware of a public report, known as “OT:ICEFALL”, detailing vulnerabilities found in multiple operational technology (OT) vendors. CISA is issuing this advisory to provide notice… Read more

  • CISA Releases Four Industrial Control Systems Advisories

    CISA released four Industrial Control Systems (ICS) advisories on June 6, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-158-01 Emerson PACSystem and Fanuc ICSA-24-158-02 Emerson Ovation ICSA-24-158-03 Mitsubishi Electric CC-Link IE TSN Industrial Managed Switch ICSA-24-158-04 Johnson Controls Software House iStar Pro Door Controller CISA encourages users… Read more

  • Mitsubishi Electric CC-Link IE TSN Industrial Managed Switch

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: CC-Link IE TSN Industrial Managed Switch Vulnerability: Allocation of Resources Without Limits or Throttling 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a temporary denial-of service (DoS) condition in the web service… Read more

  • Readout from CISA’s 2024 Second Quarter Cybersecurity Advisory Committee Meeting

    Post Content Read more

  • CISA Hosts First Annual Information and Communications Technology Supply Chain Risk Management Task Force Conference 

    Post Content Read more

  • CISA Releases Four Industrial Control Systems Advisories

    CISA released four Industrial Control Systems (ICS) advisories on June 4, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-156-01 Uniview NVR301-04S2-P4 ICSA-23-278-03 Mitsubishi Electric CC-Link IE TSN Industrial Managed Switch (Update A) ICSA-22-172-01 Mitsubishi Electric MELSEC iQ-R, Q, L Series and MELIPC Series (Update C) ICSA-24-151-02 Fuji… Read more