Siemens Interniche IP-Stack
View CSAF Summary Multiple Industrial products are affected by a vulnerability in the Interniche IP-Stack. The affected products do not properly enforce TCP sequence number validation in specific scenarios but accept values within a broad range. This could allow an unauthenticated remote attacker e.g. to interfere with connection setup, potentially leading to a denial of
-
National Instruments LabView
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose information and execute arbitrary code. The following versions of National Instruments LabView are affected: LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466,
-
Inductive Automation Ignition
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to be granted direct SYSTEM-level code execution on the host operating system running the Ignition Gateway service on Windows systems. The following versions of Inductive Automation Ignition are affected: Ignition (CVE-2025-13911) CVSS Vendor Equipment Vulnerabilities v3 6.4 Inductive Automation Inductive Automation Ignition Execution
-
CISA Releases Nine Industrial Control Systems Advisories
CISA released nine Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-352-01 Inductive Automation Ignition ICSA-25-352-02 Schneider Electric EcoStruxure Foxboro DCS Advisor ICSA-25-352-03 National Instruments LabView ICSA-25-352-04 Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electrics Products ICSA-25-352-05 Siemens Interniche IP-Stack ICSA-25-352-06 Advantech WebAccess/SCADA ICSA-25-352-07
-
CISA and Partners Release Update to Malware Analysis Report BRICKSTORM Backdoor
Today, the Cybersecurity and Infrastructure Security Agency (CISA), National Security Agency, and Canadian Centre for Cyber Security released an update to the Malware Analysis Report BRICKSTORM Backdoor with indicators of compromise (IOCs) and detection signatures for additional BRICKSTORM samples. This update provides information on additional samples, including Rust-based samples. These samples demonstrate advanced persistence and
-
CISA Adds One Known Exploited Vulnerability to Catalog
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-14733 WatchGuard Firebox Out-of-Bounds Write Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of
-
CISA Releases Seven Industrial Control Systems Advisories
CISA released seven Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-350-01 Güralp Systems FMUS (Fortimus) Series and MIN (Minimus) Series ICSA-25-350-02 Johnson Controls PowerG, IQPanel and IQHub ICSA-25-350-03 Hitachi Energy AFS, AFR and AFF Series ICSA-25-350-04 Mitsubishi Electric GT Designer3 ICSA-25-140-04 Mitsubishi Electric
-
Güralp Systems Fortimus Series, Minimus Series, and Certimus Series
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Güralp Systems Fortimus Series, Minimus Series, and Certimus Series are affected: Fortimus Series (CVE-2025-14466) Minimus Series (CVE-2025-14466) Certimus Series (CVE-2025-14466) CVSS Vendor Equipment Vulnerabilities v3 5.3 Güralp Systems Güralp Systems Fortimus Series, Minimus Series,
-
Johnson Controls PowerG, IQPanel and IQHub
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read or write encrypted traffic or perform a replay attack. The following versions of Johnson Controls PowerG, IQPanel and IQHub are affected: PowerG (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) IQHub (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) IQPanel 2 (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) IQPanel 2+ (CVE-2025-61738, CVE-2025-61739,
-
Hitachi Energy AFS, AFR and AFF Series
View CSAF Summary Successful exploitation of this vulnerability could compromise the integrity of the product data and disrupt its availability. The following versions of Hitachi Energy AFS, AFR and AFF Series are affected: AFS 660-B/C/S (CVE-2024-3596) AFS 665-B/S (CVE-2024-3596) AFS 670 v2.0 (CVE-2024-3596) AFS 650 (CVE-2024-3596) AFS 655 (CVE-2024-3596) AFS 670 (CVE-2024-3596) AFS 675 (CVE-2024-3596)