Our news

  • CISA Adds Two Known Exploited Vulnerabilities to Catalog

    CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-6204 Dassault Systèmes DELMIA Apriso Code Injection Vulnerability CVE-2025-6205 Dassault Systèmes DELMIA Apriso Missing Authorization Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.  Binding

    READ MORE

  • CISA Releases Three Industrial Control Systems Advisories

    CISA released three Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.  ICSA-25-301-01 Schneider Electric EcoStruxure ICSMA-25-301-01 Vertikal Systems Hospital Manager Backend Services ICSA-24-352-04 Schneider Electric Modicon (Update B)  CISA encourages users and administrators to review newly released ICS Advisories for technical details and mitigations. 

    READ MORE

  • Vertikal Systems Hospital Manager Backend Services

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Vertikal Systems Equipment: Hospital Manager Backend Services Vulnerabilities: Exposure of Sensitive System Information to an Unauthorized Control Sphere, Generation of Error Message Containing Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to obtain unauthorized access

    READ MORE

  • Schneider Electric EcoStruxure

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: EcoStruxure Vulnerability: Allocation of Resources Without Limits or Throttling 2. RISK EVALUATION Successful exploitation of this vulnerability could result in the loss of real-time process data from the Modicon Controller. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric

    READ MORE

  • Microsoft Releases Out-of-Band Security Update to Mitigate Windows Server Update Service Vulnerability, CVE-2025-59287

    Microsoft released an update to address a critical remote code execution vulnerability impacting Windows Server Update Service (WSUS) in Windows Server (2012, 2016, 2019, 2022, and 2025), CVE-2025-59287, that a prior update did not fully mitigate.  CISA strongly urges organizations to implement Microsoft’s updated Windows Server Update Service (WSUS) Remote Code Execution Vulnerability guidance, 1

    READ MORE

  • CISA Adds Two Known Exploited Vulnerabilities to Catalog

    CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-54236 Adobe Commerce and Magento Improper Input Validation Vulnerability CVE-2025-59287 Microsoft Windows Server Update Service (WSUS) Deserialization of Untrusted Data Vulnerability  These types of vulnerabilities are frequent attack vectors for malicious cyber actors and poses significant risks to

    READ MORE

  • NIHON KOHDEN Central Monitor CNS-6201

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: NIHON KOHDEN Equipment: Central Monitor CNS-6201 Vulnerability: NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following NIHON KOHDEN products are affected: Central

    READ MORE

  • ASKI Energy ALS-Mini-S8 and ALS-Mini-S4

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: ASKI Energy Equipment: ALS-Mini-S8, ALS-mini-s4 IP Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain full control over the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following ASKI Energy

    READ MORE

  • AutomationDirect Productivity Suite

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: AutomationDirect Equipment: Productivity Suite Vulnerabilities: Relative Path Traversal, Weak Password Recovery Mechanism for Forgotten Password, Incorrect Permission Assignment for Critical Resource, Binding to an Unrestricted IP Address 2. RISK EVALUATION Successful exploitation of these vulnerabilities could enable an attacker to execute

    READ MORE

  • CISA Releases Eight Industrial Control Systems Advisories

    CISA released eight Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.  ICSA-25-296-01 AutomationDirect Productivity Suite ICSA-25-296-02 ASKI Energy ALS-Mini-S8 and ALS-Mini-S4 ICSA-25-296-03 Veeder-Root TLS4B Automatic Tank Gauge System ICSA-25-296-04 Delta Electronics ASDA-Soft ICSMA-25-296-01 NIHON KOHDEN Central Monitor CNS-6201 ICSA-25-037-02 Schneider Electric EcoStruxure (Update C)

    READ MORE