  • Western Telematic Inc NPS Series, DSM Series, CPM Series

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Western Telematic Inc Equipment: NPS Series, DSM Series, CPM Series Vulnerability: External Control of File Name or Path 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated attacker to gain privileged access to files on the device’s filesystem.… Read more

  • Elber Communications Equipment

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Elber Equipment: Communications Equipment Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Hidden Functionality 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker unauthorized administrative access to the affected device. 3. TECHNICAL DETAILS 3.1… Read more

  • CISA Releases Fact Sheet Detailing Embedded Backdoor Function of Contec CMS8000 Firmware

    CISA released a fact sheet, [Contec CMS8000 Contains a Backdoor], detailing an analysis of three firmware package versions of the Contec CMS8000, a patient monitor used by the U.S. Healthcare and Public Health (HPH) sector. Analysts discovered that an embedded backdoor function with a hard-coded IP address, CWE – 912: Hidden Functionality (CVE-2025-0626), and functionality… Read more

  • Rockwell Automation FactoryTalk AssetCentre

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk AssetCentre Vulnerabilities: Inadequate Encryption Strength, Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to extract passwords, access, credentials, or impersonate other users. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following… Read more

  • Contec Health CMS8000 Patient Monitor

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Contec Health Equipment: CMS8000 Patient Monitor Vulnerabilities: Out-of-bounds Write, Hidden Functionality (Backdoor), Privacy Leakage 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to remotely send specially formatted UDP requests or connect to an unknown external network that… Read more

  • New Rock Technologies Cloud Connected Devices

    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: New Rock Technologies Equipment: Cloud Connected Devices Vulnerabilities: Improper Neutralization of Special Elements used in an OS Command (‘OS Command Injection’), Improper Neutralization of Wildcards or Matching Symbols 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker full… Read more

  • Rockwell Automation KEPServer

    View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: KEPServer Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could cause the device to crash. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation’s KEPServer are affected: KEPServer: Versions 6.0 to… Read more

  • Schneider Electric System Monitor Application in Harmony and Pro-face PS5000 Legacy Industrial PCs

    View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Harmony Industrial PC, Pro-face Industrial PC Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access sensitive information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider… Read more

  • CISA Releases Eight Industrial Control Systems Advisories

    CISA released eight Industrial Control Systems (ICS) advisories on January 30, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-030-01 Hitachi Energy UNEM ICSA-25-030-02 New Rock Technologies Cloud Connected Devices ICSA-25-030-03 Schneider Electric System Monitor Application in Harmony and Pro-face PS5000 Legacy Industrial PCs ICSA-25-030-04 Rockwell Automation KEPServer… Read more

  • Hitachi Energy UNEM

    View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: UNEM Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Argument Injection, Heap-based Buffer Overflow, Improper Certificate Validation, Use of Hard-coded Password, Improper Restriction of Excessive Authentication Attempts, Cleartext Storage of Sensitive Information, Incorrect User Management 2. RISK… Read more